DocumentCode
1819444
Title
Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines
Author
Farahani, M. ; Borsi, H. ; Gockenbach, E.
Author_Institution
Inst. of Electr. Power Syst., Hannover Univ., Germany
Volume
1
fYear
2003
fDate
1-5 June 2003
Firstpage
290
Abstract
In this work the possibility of the dielectric response measurement for the evaluation of the actual status of insulation system of high voltage rotating machines are investigated. As test object, model stator bars were used, which are close to real stator bars of high voltage rotating machines. An accelerated ageing procedure was applied to the model bars and the dielectric response was measured in time domain. The dielectric response function was calculated from depolarization current measuring results and the change of this function was evaluated.
Keywords
ageing; dielectric depolarisation; dielectric function; dielectric measurement; electric machines; insulation testing; machine insulation; stators; accelerated ageing; depolarization current; dielectric response function; dielectric response measurement; high voltage rotating machines; insulation systems; real stator bars; time domain; Accelerated aging; Dielectric devices; Dielectric measurements; Dielectrics and electrical insulation; Rotating machines; Rotation measurement; Stator bars; Testing; Time measurement; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and Applications of Dielectric Materials, 2003. Proceedings of the 7th International Conference on
ISSN
1081-7735
Print_ISBN
0-7803-7725-7
Type
conf
DOI
10.1109/ICPADM.2003.1218409
Filename
1218409
Link To Document