• DocumentCode
    1819636
  • Title

    Spark damage studies of microgap gas chambers with various anode strip metals

  • Author

    Cho, H.S. ; Hong, W.S. ; Palaio, N. ; Kadyk, J. ; Luk, K.B. ; Perez-Mendez, V. ; Joo, K.S. ; Vujic, J.

  • Author_Institution
    Dept. of Nucl. Eng., California Univ., Berkeley, CA, USA
  • Volume
    1
  • fYear
    1996
  • fDate
    2-9 Nov 1996
  • Firstpage
    224
  • Abstract
    Since the effects of spark damage by discharges and aging are very sensitive to metal used for anode strips, several microgap gas chambers (MGCs) have been fabricated with various anode strip metals: aluminum, gold, chromium, nickel, and titanium-tungsten, and a systematic study of spark damage effects has been made to compare their relative sensitivity to failure, over a range of electrical discharge energies. The results of aging studies are presented separately
  • Keywords
    aluminium; chromium; gold; nickel; position sensitive particle detectors; sparks; titanium alloys; Al; Au; Cr; Ni; Ti-W; anode strip metals; electrical discharge energies; failure; microgap gas chambers; spark damage; Aging; Anodes; Chromium; Electrodes; Gold; Insulation; Physics; Sparks; Strips; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-3534-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1996.590946
  • Filename
    590946