Abstract :
Since the effects of spark damage by discharges and aging are very sensitive to metal used for anode strips, several microgap gas chambers (MGCs) have been fabricated with various anode strip metals: aluminum, gold, chromium, nickel, and titanium-tungsten, and a systematic study of spark damage effects has been made to compare their relative sensitivity to failure, over a range of electrical discharge energies. The results of aging studies are presented separately
Keywords :
aluminium; chromium; gold; nickel; position sensitive particle detectors; sparks; titanium alloys; Al; Au; Cr; Ni; Ti-W; anode strip metals; electrical discharge energies; failure; microgap gas chambers; spark damage; Aging; Anodes; Chromium; Electrodes; Gold; Insulation; Physics; Sparks; Strips; Wire;