    Fault diagnostic testing using Partial Discharge measurements on High Voltage rotating machines

  • Author

    Smeeton, Paul ; Bousbaine, Amar

  • Author_Institution
    ERIKS UK, Chesterfield, UK
  • fYear
    2009
  • fDate
    1-4 Sept. 2009
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This paper addresses the testing of High Voltage (HV) insulation systems associated with large motors and generators. The condition of HV insulation systems associated with rotating machines using Partial Discharge (PD) as a predictive tool alongside the other techniques will be assessed. These other tests include the measurement of Insulation Resistances (IR), and the equivalent parallel resistance and capacitance to calculate tan delta values.
  • Keywords
    fault diagnosis; insulation testing; machine testing; partial discharge measurement; fault diagnostic testing; high voltage insulation systems; high voltage rotating machines; insulation resistances; partial discharge measurements; predictive tool; Cogeneration; Distributed power generation; Mesh generation; Partial discharge measurement; Power generation; Rotating machines; Solar power generation; Testing; Voltage; Wind energy generation;