  • Abstract
    We present a read-out solution for a bolometric detector of large mass. It consists of a voltage-sensitive preamplifier, having very low series and parallel input noise, thanks to the use of a pair of selected silicon JFETs at the input. Very good electrical characteristics were obtained. DC power supply rejection ratio, thermal drift of input offset voltage and input leakage current are minimized by using novel circuit solutions. Parallel noise behavior was also investigated using a new measurement method capable to be sensitive to shot noise generated by very small currents (tens of fA)
  • Keywords
    bolometers; detector circuits; leakage currents; nuclear electronics; particle detectors; preamplifiers; shot noise; DC power supply rejection ratio; Si JFET; electrical characteristics; input leakage current; input offset voltage; large mass bolometric detector; low DC drift read-out system; parallel noise behavior; shot noise; voltage-sensitive preamplifier; Circuit noise; Detectors; Electric variables; JFETs; Leakage current; Noise generators; Power supplies; Preamplifiers; Silicon; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-3534-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1996.591044
  • Filename
    591044