DocumentCode
1821678
Title
A TPC for a future linear collider
Author
Wienemann, Peter
Author_Institution
Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany
Volume
1
fYear
2003
fDate
19-25 Oct. 2003
Firstpage
540
Abstract
A large Time Projection Chamber (TPC) has been proposed as main tracking device for a detector at a future linear collider. The ambitious physics program poses unprecedented requirements on the precision of the TPC. A comprehensive R&D program is currently being accomplished to address this challenge. Emphasis is put on studying Gas Electron Multipliers and Micromegas as an alternative for conventional wire based gas amplification systems. An overview over recent results from the ongoing R&D efforts is presented.
Keywords
Monte Carlo methods; electron multiplier detectors; linear colliders; time projection chambers; Monte Carlo prediction; R&D program; central tracker; future linear collider; gas electron multipliers; large time projection chamber; micromegas; optimal feedback; Detectors; Electron multipliers; Extraterrestrial measurements; Large Hadron Collider; Magnetic fields; Particle measurements; Particle tracking; Physics; Research and development; Wire;