DocumentCode :
1822015
Title :
Engine-driven generator interactive three-phase switched-mode PFC converter and its performance evaluations
Author :
Hirachi, K. ; Nishimura, K. ; Baba, N. ; Gamage, L. ; Chibani, A. ; Nakaoka, M.
Author_Institution :
Res. & Dev. Div., Yuasa Corp., Osaka, Japan
Volume :
2
fYear :
1997
fDate :
7-11 Jul 1997
Firstpage :
612
Abstract :
A discontinuous current mode control scheme for a single phase AC-DC power converter with an active power filtering function and power factor correction scheme has attracted special interest in industrial and telecommunication energy plants. This control strategy has the practical advantages of a simple control procedure configuration and cost-effectiveness. However, for emergency engine-driven generators, a three-phase input power PFC converter has not been effectively adopted because the characteristics of conventional control schemes have some disadvantages for engine-driven generator interactive three-phase AC mains schemes. Thus, a new and simple PFC power converter circuit configuration with a discontinuous current mode control scheme suitable for engine-driven generator interconnected with three-phase AC mains is proposed. This paper presents the operating principle and unique features of the cost-effective engine-driven generator interactive three-phase active PFC converter circuit topology proposed here, along with harmonic current and PFC performance evaluations on the basis of simulation results of this converter as compared with two conventional types of three-phase PFC converters
Keywords :
AC-DC power convertors; active filters; control system analysis; control system synthesis; electric current control; harmonic distortion; power factor correction; power filters; power system harmonics; power system interconnection; rectifying circuits; standby generators; switched mode power supplies; control design; control simulation; control strategy; discontinuous current mode control scheme; emergency engine-driven generators; harmonic current; interactive three-phase AC mains schemes; mains interconnection; operating principle; performance evaluations; power factor correcting convertor; three-phase switched-mode power converter; AC generators; AC-DC power converters; Active filters; Character generation; Communication industry; Industrial control; Power factor correction; Power generation; Telecommunication control; Telecommunication switching;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics, 1997. ISIE '97., Proceedings of the IEEE International Symposium on
Conference_Location :
Guimaraes
Print_ISBN :
0-7803-3936-3
Type :
conf
DOI :
10.1109/ISIE.1997.649033
Filename :
649033
Link To Document :
بازگشت