DocumentCode
182209
Title
Development of big-size impregnated scandate dispenser cathode
Author
Hui Wang ; Zhiqiang Yu ; Wensheng Shao ; Ji Li ; Yan Men ; Anmin Yang ; Liansheng Xia ; Jinshui Shi
Author_Institution
Beijing Vacuum Electron. Res. Inst., Beijing, China
fYear
2014
fDate
22-24 April 2014
Firstpage
61
Lastpage
62
Abstract
The big-size (Φ100, 135, and 155mm) scandate dispenser cathodes have been fabricated in BVERI and tested in injector system of LIA. The results show that impregnated scandate cathodes which have better emission performance can be applied as the electron source in LIA and satisfied the requirement of the LIA. The pulse current of both Φ135 and Φ155mm cathode assemblies is more than 2000A and the current density is more than 14 A/cm2. At the same time, the cathode has good emission stability and repetition with respect to single pulse and three-pulse modes.
Keywords
cathodes; current density; electron field emission; BVERI; LIA injector system; big-size impregnated scandate dispenser cathode; current density; electron source; emission performance; emission stability; single pulse modes; three-pulse modes; Assembly; Cathodes; Current density; Electron sources; Heating; Temperature distribution; Thermal stability; activation; emission; heater; outgassing; scandate cathode;
fLanguage
English
Publisher
ieee
Conference_Titel
Vacuum Electronics Conference, IEEE International
Conference_Location
Monterey, CA
Type
conf
DOI
10.1109/IVEC.2014.6857490
Filename
6857490