• DocumentCode
    1822352
  • Title

    Inverter voltage drop-free recursive least-squares parameter identification of a PWM inverter-fed induction motor at standstill

  • Author

    Bertoluzzo, Manuels ; Buja, Giusepps S. ; Menis, Roberto

  • Author_Institution
    Dept. of Electr. Eng., Padova Univ., Italy
  • Volume
    2
  • fYear
    1997
  • fDate
    7-11 Jul 1997
  • Firstpage
    649
  • Abstract
    The paper presents a procedure for identifying the parameters of a PWM voltage inverter-fed induction motor (M) at standstill, based on the recursive least-squares (RLS) technique. The procedure does not require the knowledge of the voltage drop on the inverter, thus simplifying the identification process and increasing the accuracy of the results. The paper starts by addressing the issue of the parameter identification in a PWM inverter-fed IM at standstill. Then the solution which makes the identification free from the inverter voltage illustrated and the procedure built upon it is formulated. Finally, the equipment arranged for executing the identification tests is described and the results obtained from the experiments are shown
  • Keywords
    PWM invertors; PWM inverter-fed induction motor; identification process simplification; recursive least-squares parameter identification; standstill; voltage drop-free parameter identification; Control systems; Hardware; Induction motors; Manufacturing; Parameter estimation; Pulse width modulation inverters; Resonance light scattering; Stators; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, 1997. ISIE '97., Proceedings of the IEEE International Symposium on
  • Conference_Location
    Guimaraes
  • Print_ISBN
    0-7803-3936-3
  • Type

    conf

  • DOI
    10.1109/ISIE.1997.649043
  • Filename
    649043