DocumentCode
1822737
Title
Computer-Aided Evaluation System for Parkinson´s Disease Using Image Registration and Labeling
Author
Jiann-Der Lee ; Cheng-Wei Chen ; Chung-Hsien Huang
Author_Institution
Chang Gung Univ., Taoyuan
fYear
2007
fDate
22-26 Aug. 2007
Firstpage
844
Lastpage
847
Abstract
Single photon emission computed tomography image (SPECT) of dopamine transporter with 99mTc-TRODAT-l has recently been proposed to be a valuable and feasible means of assessing the integrity of dopamine neurons. In order to measure the specific-to-nonspecific binding ratio of the nuclear medicine within the specific-binding tissues, i.e. putamens and caudate nuclei, the corresponding MRI is needed to be registered to SPECT for bounding the regions of interest. Therefore, an automatic labeling algorithm which enables contouring the putamens and caudate nuclei is necessary because segmenting these tissues manually from MRI costs tons of time and energy of physicians. We have built a computer-aided clinical diagnosis system which integrates MRI/SPECT registration and MRI labeling for the evaluation of Parkinson´s disease. Clinical MRI and SPECT data including eighteen healthy subjects and thirteen patients were involved to validate the performance of the proposed system.
Keywords
biomedical MRI; diseases; image registration; image segmentation; medical image processing; single photon emission computed tomography; MRI; Parkinson disease; SPECT; automatic labeling algorithm; caudate nuclei; clinical diagnosis system; computer-aided evaluation system; dopamine neurons; dopamine transporter; image registration; image segmentation; nuclear medicine; putamens; single photon emission computed tomography image; specific-binding tissues; Clinical diagnosis; Costs; Image registration; Labeling; Magnetic resonance imaging; Neurons; Nuclear measurements; Nuclear medicine; Parkinson´s disease; Single photon emission computed tomography; Algorithms; Humans; Image Interpretation, Computer-Assisted; Magnetic Resonance Imaging; Parkinson Disease; Putamen; Reproducibility of Results; Sensitivity and Specificity; Staining and Labeling; Subtraction Technique; Tomography, Emission-Computed, Single-Photon;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
Conference_Location
Lyon
ISSN
1557-170X
Print_ISBN
978-1-4244-0787-3
Type
conf
DOI
10.1109/IEMBS.2007.4352422
Filename
4352422
Link To Document