Title :
The influence of signal pick-up method on measuring precision of tan δ with a quasi-synchronous sampling harmonic analysis method
Author :
Chen, Jiong ; Yin, Yi ; Xiao, Deng Ming ; Wei, Xin Lao ; Wang, Yong Hong ; Ye, Qing Hua
Author_Institution :
Dept. of Electr. Eng., Shanghai Jiao Tong Univ., China
Abstract :
The paper introduces the measurement of tan δ with a quasi-synchronous sampling harmonic analysis method firstly. The principle and the algorithm for harmonic analyzing under the condition of quasi-synchronous sample are described. It is shown, through an analysis about many influencing facts, that this method has high precision and good anti-disturbance characteristics, but the precision of this method is influenced by the methods of signal pick-up. The paper analyses the influence of different methods of signal pick-up on the precision of measurement.
Keywords :
dielectric losses; harmonic analysis; quasisynchronous sampling harmonic analysis; signal pick up method; Bridge circuits; Dielectric measurements; Electric variables measurement; Electromagnetic measurements; Harmonic analysis; Paper technology; Power harmonic filters; Sampling methods; Signal analysis; Voltage;
Conference_Titel :
Properties and Applications of Dielectric Materials, 2003. Proceedings of the 7th International Conference on
Print_ISBN :
0-7803-7725-7
DOI :
10.1109/ICPADM.2003.1218542