DocumentCode :
1823364
Title :
Cascaded multilevel inverters fault control
Author :
Farzaneh, A. ; Nazarzadeh, Jalal
Author_Institution :
Sama Tech. & Vocational Training Coll., Islamic Azad Univ., Islamshahr, Iran
fYear :
2011
fDate :
8-10 Sept. 2011
Firstpage :
164
Lastpage :
168
Abstract :
This paper proposes a new control method to increase cascaded multilevel inverters (GMl) efficiency at faulty condition. The influence of most probability fault on GMl with carrier based pulse width modulation (CBPWM) is investigated and the maximum output voltage is derived without elimination of faulty power cell. This method is able to produce balanced phase voltage on faulty phase. In addition proposed method can be used in the H-bridge cascaded multilevel inverter of any voltage levels. Simulation results are provided.
Keywords :
PWM invertors; fault diagnosis; CBPWM; GMl efficiency; H-bridge cascaded multilevel inverter; balanced phase voltage; carrier based pulse width modulation; cascaded multilevel inverters fault control; fault condition; probability fault; Carrier based pulse width modulation; Multilevel inverters; Open circuit fault;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Power Electronics and 2011 Electromotion Joint Conference (ACEMP), 2011 International Aegean Conference on
Conference_Location :
Istanbul
Print_ISBN :
978-1-4673-5004-4
Electronic_ISBN :
978-1-4673-5002-0
Type :
conf
DOI :
10.1109/ACEMP.2011.6490588