    This study is a kinematic analysis of the joints of the rearfoot using two kinematic measurement techniques. An unembalmed cadaver foot and ankle was examined using external motion analysis and three-dimensional magnetic resonance imaging (3D MRI). The authors found a net of 30° of motion at the subtalar joint as the foot moved from 20° of pronation to 50° of supination. They also measured 30° of relative motion between the talus and navicular and 10° between the calcaneus and cuboid
  • Keywords
    biomechanics; biomedical NMR; image reconstruction; kinematics; medical image processing; 3D MRI reconstruction; cadaver study; calcaneus; cuboid; external motion analysis; navicular; pronation; rearfoot kinematics; stereometry; subtalar joint; supination; talus; three-dimensional magnetic resonance imaging; unembalmed cadaver foot/ankle; Biomedical imaging; Bones; Cadaver; Foot; Image reconstruction; Joints; Kinematics; Magnetic resonance imaging; Measurement techniques; Motion analysis; Motion measurement; Position measurement; Rotation measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1994. Engineering Advances: New Opportunities for Biomedical Engineers. Proceedings of the 16th Annual International Conference of the IEEE
  • Conference_Location
    Baltimore, MD
  • Print_ISBN
    0-7803-2050-6
  • Type

    conf

  • DOI
    10.1109/IEMBS.1994.411902
  • Filename
    411902