DocumentCode
1824018
Title
Experimental investigation of new indices of broken rotor bar in induction motor
Author
Oumaamar, M. El K. ; Razik, H. ; Rezzoug, Abderrezak ; Chemali, Hamimi ; Khezzar, Abdelmalek
Author_Institution
GREEN-UHP, Univ. Henri Poincare - Nancy, Vandoeuvre lès Nancy, France
fYear
2011
fDate
8-10 Sept. 2011
Firstpage
304
Lastpage
307
Abstract
Most of rotor related faults in three-phase induction motors are due to broken rotor bars and end-ring defects. Nowadays Inductions motors are more frequently used with inverters which make the diagnosis process more complicated. Furthermore, some manufacturers of induction machines mount converters (i.e. rectifier and inverter) directly onto the machine, which makes the stator current unattainable for diagnosis. In order to overcome these drawbacks, the authors propose to analyze new motor fault signatures in the supply line current of the inverter. Experimental and simulation results show a total agreement and confirm the effectiveness of the present study.
Keywords
fault diagnosis; induction motors; invertors; broken rotor bar indices; converters; end-ring defects; fault diagnosis process; induction machines; inverters; motor fault signatures; supply line current; three-phase induction motors; Fault diagnosis; broken rotor bars faults; induction motors; inverter;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Power Electronics and 2011 Electromotion Joint Conference (ACEMP), 2011 International Aegean Conference on
Conference_Location
Istanbul
Print_ISBN
978-1-4673-5004-4
Electronic_ISBN
978-1-4673-5002-0
Type
conf
DOI
10.1109/ACEMP.2011.6490615
Filename
6490615
Link To Document