• DocumentCode
    1824759
  • Title

    The statistical properties of PD distribution in oil-impregnated insulation at elevated temperature

  • Author

    Ariastina, W.G. ; Khawaja, R.H. ; Blackburn, T.R.

  • Author_Institution
    Sch. of Electr. Eng. & Telecommun., Univ. of New South Wales, Sydney, NSW, Australia
  • Volume
    3
  • fYear
    2003
  • fDate
    1-5 June 2003
  • Firstpage
    1116
  • Abstract
    This paper presents a study of the properties of partial discharges at elevated temperature. Particular interest was given to new and aged oil-impregnated insulation as applied in power and instrument transformers. The data analysis was focused on the PD quantities that include the peak and average PD magnitudes and the PD repetition rate. In addition to the PD quantities, an investigation of the discharge characteristics using statistical moments was also conducted. Results indicated that the PD quantities and the characteristics of their distributions are greatly affected by the temperature change. Variation in the PD activity was found to be considerable and very dependent on the insulation condition.
  • Keywords
    impregnated insulation; instrument transformers; partial discharge measurement; power transformer insulation; statistical analysis; transformer oil; instrument transformer; oil impregnated insulation; partial discharge distribution; power transformer; statistical moment; statistical properties; Aging; Dielectrics and electrical insulation; Heating; Oil insulation; Partial discharges; Petroleum; Power transformer insulation; Temperature distribution; Testing; Thermal stresses;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 2003. Proceedings of the 7th International Conference on
  • ISSN
    1081-7735
  • Print_ISBN
    0-7803-7725-7
  • Type

    conf

  • DOI
    10.1109/ICPADM.2003.1218619
  • Filename
    1218619