DocumentCode
1824942
Title
Vertex detection in a stack of Si-drift detectors for high resolution gamma-ray imaging
Author
Walenta, A.H. ; Brill, A. ; Castoldi, A. ; Conka-Nurdan, T. ; Guazzoni, C. ; Hartmann, K. ; Longoni, A. ; Nurdan, K. ; Strüder, L.
Author_Institution
Dept. of Phys., Siegen Univ., Germany
Volume
3
fYear
2003
fDate
19-25 Oct. 2003
Firstpage
1815
Abstract
Usually the position resolution in imaging applications with gamma rays is limited due to the range of secondary reaction products to a few mm. Here a new approach will be presented using the vertex of the gamma interaction as the quantity for position measurement. Because the dominant interaction is the Compton effect the vertex detection method as used in particle physics needs a number of essential modifications. Therefore a detector system is investigated consisting of a stack of Si-drift detectors for the vertex detection of the first Compton interaction and a secondary absorption detector where the position of the scattered photon is detected. A number of effects and possible solutions will be discussed including depth of interaction measurement and track reconstruction of the Compton electron which yields useful information. Another very promising approach of measuring the track projection as in a TPC (time projection chamber) will be presented including first successful measurements in a gas detector. Because the expected rate in the first and second detector is of the order of 1 MHz and 10 MHz respectively the concept of read out electronics and data processing based on VLSI custom chips for signal shaping and first buffering and digital pipe-line processors based on FPGA s is presented. Finally a full system for small animal imaging based on the principle of a Compton Camera will be discussed in terms of achievable resolution and sensitivity.
Keywords
Compton effect; gamma-ray detection; position sensitive particle detectors; radioisotope imaging; readout electronics; silicon radiation detectors; time projection chambers; 1 MHz; 10 MHz; Compton Camera; Compton effect; FPGA; Si-drift detectors; VLSI custom chips; buffering; data processing; digital pipe-line processors; gas detector; high resolution gamma-ray imaging; position measurement; read out electronics; secondary absorption detector; signal shaping; small animal imaging; time projection chamber; track reconstruction; vertex detection; Absorption; Gamma ray detection; Gamma ray detectors; Gamma rays; High-resolution imaging; Image resolution; Nuclear imaging; Optical imaging; Position measurement; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2003 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8257-9
Type
conf
DOI
10.1109/NSSMIC.2003.1352231
Filename
1352231
Link To Document