• DocumentCode
    182585
  • Title

    A potential failure reason for Spindt cathodes in high current applications

  • Author

    Xinghui Li ; Guodong Bai ; Hanyan Li ; Mingqing Ding ; Jinjun Feng ; Fujiang Liao

  • Author_Institution
    Nat. Key Lab. of Sci. & Technol. on Vacuum Electron., Beijing Vacuum Electron. Res. Inst., Beijing, China
  • fYear
    2014
  • fDate
    22-24 April 2014
  • Firstpage
    509
  • Lastpage
    510
  • Abstract
    We believe one main reason for Spindt cathodes failure in initial testing is metal particle adhesion produced in cone formation process. It is also a potential failure reason in high current applications. Preliminary experiments show megahertz ultrasonic cleaning is effective in removing the particles but further work is still need.
  • Keywords
    adhesion; failure analysis; flashover; ultrasonic cleaning; Spindt cathodes failure; cone formation process; high current applications; megahertz ultrasonic cleaning; metal particle adhesion; Acoustics; Adhesives; Cathodes; Cavity resonators; Cleaning; Logic gates; Metals; Spindt cathode; cathode failure; high current application; megahertz ultrasonic cleaning; metal particle adhesion;