• DocumentCode
    1826900
  • Title

    Study of differential pressure method for air leak detection based on tempretrue

  • Author

    Tao, Wang ; Qin, Mao ; Wei, Fan ; Junzheng, Wang

  • Author_Institution
    Sch. of Autom., Beijing Inst. of Technol., Beijing, China
  • fYear
    2011
  • fDate
    17-20 Aug. 2011
  • Firstpage
    259
  • Lastpage
    263
  • Abstract
    The differential pressure method is widely used nowadays for air leak detection[1]. In this method, a master tank, which is leak-tight, a tested tank are simultaneously charged to a certain pressure and then closed off each other. If there is air leak in the tested tank, the air leak can be detected from the different pressure occurs between the two tanks. Since both tanks temperature is inconsistent in detection process will lead to changes in pressure affect the detection precision. Although, if the tested tank is leak-tight. This problem has become the major concern in this research. This paper obtained by simulation of temperature, thermal conductivity, container volume and other parameters on the impact of differential effects of the actual amount of leakage detection provides a theoretical basis.
  • Keywords
    gas sensors; leak detection; pressure sensors; tanks (containers); thermal conductivity; air leak detection; differential pressure method; leak-tight tested tank; master tank; thermal conductivity; Containers; Heat transfer; Leak detection; Pressure measurement; Temperature measurement; Time measurement; Valves; differential pressure; leakage; temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fluid Power and Mechatronics (FPM), 2011 International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-8451-5
  • Type

    conf

  • DOI
    10.1109/FPM.2011.6045769
  • Filename
    6045769