• DocumentCode
    1831236
  • Title

    Frequency measurement and disturbance monitoring using piezoelectric transformers

  • Author

    Lele, Sneha ; Sobot, Robert ; Sidhu, Tarlochan

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Western Ontario, London, ON, Canada
  • fYear
    2012
  • fDate
    24-25 Feb. 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    A novel line monitoring methodology based on piezoelectric transformer (PT) is proposed. The frequency range of operation and magnitude levels for voltage sensing are discussed and experimental results are presented. The experimental results show that a PT sustains high input voltages at power-line frequency and steps it down while stepping up the transient high frequency tones. Hence, an unexplored low-frequency region of operation of the PT is exploited and proposed in line frequency measurement and disturbance monitoring.
  • Keywords
    frequency measurement; piezoelectric devices; transformers; PT; disturbance monitoring; frequency measurement; line monitoring methodology; piezoelectric transformers; power-line frequency; transient high frequency tones; unexplored low-frequency region; Delay; Frequency measurement; Integrated circuit modeling; Monitoring; Resonant frequency; Transient analysis; Voltage measurement; frequency monitoring; harmonic; piezoelectric transformer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Conference at Illinois (PECI), 2012 IEEE
  • Conference_Location
    Champaign, IL
  • Print_ISBN
    978-1-4577-1681-2
  • Electronic_ISBN
    978-1-4577-1682-9
  • Type

    conf

  • DOI
    10.1109/PECI.2012.6184615
  • Filename
    6184615