Title :
Efficient analytical scatter modeling in fully 3-D iterative single photon emission computed tomography reconstruction
Author :
Ma, Tianyu ; Jin, Yongjie
Author_Institution :
Dept. of Eng. Phys., Tsinghua Univ., Beijing, China
Abstract :
Quantitative single photon emission computed tomography (SPECT) images are degraded by several physical factors, among which Compton scatter is the most difficult to compensate. An analytical scatter modeling (ASM) method is proposed to model scatter in SPECT. The reconstruction architecture includes following steps: 1) a look-up table describing patient independent factors was precalculated, and a numerical integration method based on number theory resulted in 1 to 2 order of magnitude speed up in precalculation. 2) The transition matrix was generated based on the patient-specific attenuation map. 3) OSEM reconstruction was performed with an unmatched projector/backprojector. ASM was validated by Monte-Carlo simulation, considering the case of the point source in a homogeneous and a non-homogeneous medium. Experiment was performed using a HAMAMATSU BHP6601 SPECT and a SPECT performance phantom. Projection data was reconstructed by OSEM method with/without ASM, filtered back projection(FBP) and FBP with dual energy window (DEW) scatter correction. Results show that OSEM/ASM is more accurate and gain higher contrast than others. For a 64 ×64 × 64 image array. The computation time of the transition matrix is 80 min, and the reconstruction takes 4 min per iteration on a 1.54 GHz processor PC. This work proposed a computationally efficient method to model scatter in SPECT reconstruction within clinically acceptable time.
Keywords :
Compton effect; Monte Carlo methods; filtering theory; image reconstruction; iterative methods; medical image processing; phantoms; physiological models; single photon emission computed tomography; 1.54 GHz; 80 min; Compton scatter; HAMAMATSU BHP6601 SPECT; Monte Carlo simulation; OSEM reconstruction; SPECT performance phantom; dual energy window scatter correction; efficient analytical scatter modeling; filtered back projection; fully 3D iterative single photon emission computed tomography reconstruction; numerical integration method; patient independent factors; patient-specific attenuation map; transition matrix; unmatched projector/backprojector; Analytical models; Attenuation; Computer architecture; Degradation; Electromagnetic scattering; Image reconstruction; Imaging phantoms; Particle scattering; Single photon emission computed tomography; Table lookup;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2003 IEEE
Print_ISBN :
0-7803-8257-9
DOI :
10.1109/NSSMIC.2003.1352562