MMAVERIC - A Calibration Technique for MIMICs
Author
Sequeira, H.B. ; Trippe, M.M. ; Jakhete, R.
Author_Institution
Martin Marietta Laboratories/GAMMA Monolithics(Martin Marietta Corporation and Alpha Industries, Inc.), Baltimore, MD 21227
Volume
12
fYear
1987
fDate
3-4 Dec. 1987
Firstpage
3
Lastpage
12
Abstract
MMAVERIC is applicable to both one- and two-port calibrations and yields significant information besides the usual error terms. For example, it determines one of the standards used in the calibration, and also furnishes the transmission line´s loss and dispersion, which are rarely known accurately enough in MIMIC environments. Moreover, MMAVERIC calculates the uncertainties of the output quantities, and incorporates measurement redundancy to produce stable output quantities despite a high level of fluctuation in the input (raw) data. The ability to accept or reject a calibration at the raw data level is expected to significantly increase throughput and decrease the cost of MIMIC testing.
Keywords
Calibration; Circuit testing; Frequency measurement; Frequency response; Millimeter wave integrated circuits; Monolithic integrated circuits; Redundancy; Reflection; Transmission line measurements; Transmission line theory;