DocumentCode
1834226
Title
Calibration method of amplitude and phase consistency of digital variable polarization radar receiving system
Author
Liu, Jianxun ; Yu, Xiang ; Liang, Chaojie ; Sun, Ke ; Sun, Houjun
Author_Institution
Sch. of Inf. & Electron., Beijing Inst. of Technol., Beijing, China
fYear
2011
fDate
22-25 May 2011
Firstpage
44
Lastpage
47
Abstract
In order to calibrate the consistency of the amplitude and phase of four-channel digital variable polarization monopulse radar receiving system, a calibration method based on exterior space calibration is proposed. Making use of this method, author completes the calibration in the darkroom. After calibration, the experimental results show that in receiving pattern the polarization purity, null depth of difference beam and sidelobe balance are improved. The results demonstrate the method is correct and feasible.
Keywords
electromagnetic wave polarisation; radar signal processing; amplitude consistency; calibration method; exterior space calibration; four channel digital variable polarization; monopulse radar receiving system; phase consistency; polarization purity; sidelobe balance; Calibration; Polarization; Radar; Radar antennas; Receiving antennas; Transmitting antennas; Amplitude-phase consistency; DBF; calibration; variable polarization;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Technology & Computational Electromagnetics (ICMTCE), 2011 IEEE International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-8556-7
Type
conf
DOI
10.1109/ICMTCE.2011.5915162
Filename
5915162
Link To Document