DocumentCode :
1834243
Title :
First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
Author :
Chmeissani, M. ; Frojdh, C. ; Gal, O. ; Llopart, X. ; Ludwig, J. ; Manach, E. ; Ponchut, C. ; Russo, P. ; Tlustos, L.
Author_Institution :
Institut de Fisica d´´Altes Energies, Barcelona, Spain
Volume :
5
fYear :
2003
fDate :
19-25 Oct. 2003
Firstpage :
3394
Abstract :
We present preliminary tests of hybrid pixel detectors consisting of the Medipix2 readout chip bump-bonded to a 1-mm thick CdTe pixel detector. This room temperature imaging system for single photon counting has been developed within the Medipix2 European Collaboration for various imaging applications with X-rays and gamma rays, including dental radiography, mammography, synchrotron radiation, nuclear medicine, radiation monitoring in nuclear facilities. The Medipix2+CdTe hybrid detector features 256x256 square pixels, a pitch of 55 μm, a sensitive area of 14x14 mm2. Here we analyzed the quality of the detector and bump-bonding and the response to nuclear radiation of the first CdTe hybrids. The CdTe pixel detectors, with Pt contacts, showed an ohmic response when negatively biased to less than 100 V (electrons collection mode). Tests were also performed in holes collection mode, where a non-resistive behaviour was observed above +15 V. We performed a series of imaging tests with gamma radioactive sources and with an X-ray tube. In flood illumination, we observed for all detectors the presence of numerous, stable small-scale structures in the form of small circles, with the central pixels showing a reduced counting efficiency with respect to the periphery (in electrons counting regime).
Keywords :
X-ray imaging; X-ray tubes; application specific integrated circuits; diagnostic radiography; gamma-ray detection; mammography; nuclear electronics; ohmic contacts; photon counting; position sensitive particle detectors; radiation monitoring; radioisotope imaging; readout electronics; semiconductor counters; synchrotron radiation; 1 mm; 55 mum; CdTe photon counting pixel detector; Medipix2 readout chip; Medipix2+CdTe hybrid detector; Pt contacts; X-ray imaging applications; X-ray tube; central pixels; counting efficiency; dental radiography; detector quality; electrons collection mode; electrons counting regime; flood illumination; gamma radioactive sources; gamma ray imaging applications; holes collection mode; hybrid pixel detectors; imaging tests; mammography; negative bias; nonresistive behavior; nuclear facilities; nuclear medicine; nuclear radiation response; ohmic response; radiation monitoring; room temperature imaging system; single photon counting; stable small-scale structures; synchrotron radiation; Collaboration; Dentistry; Detectors; Electrons; Gamma rays; Optical imaging; Performance evaluation; Temperature; Testing; X-rays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2003 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8257-9
Type :
conf
DOI :
10.1109/NSSMIC.2003.1352633
Filename :
1352633
Link To Document :
بازگشت