• DocumentCode
    1834514
  • Title

    NUFFT-based near-field imaging method for target scattering diagnostics

  • Author

    Zhao, Guoqiang ; Li, Shiyong ; Zhang, Zhuo ; Liu, Baiyin

  • Author_Institution
    Beijing Inst. of Technol., Beijing, China
  • fYear
    2011
  • fDate
    22-25 May 2011
  • Firstpage
    104
  • Lastpage
    106
  • Abstract
    A near-field imaging method based on the Non-uniform fast Fourier transformation (NUFFT) is presented. The NUFFT is incorporated in the computed tomography (CT) method in replace of the inverse fast Fourier transformation (IFFT) and the one-dimensional (1-D) interpolation. Comparisons with the conventional near-field filtered back projection (FBP) method are performed. Simulations demonstrate that the NUFFT-based near-field imaging method shows higher precision and lower side-lobes than the FBP method.
  • Keywords
    X-ray imaging; computerised tomography; radar imaging; 1D interpolation; NUFFT; computed tomography; inverse fast Fourier transformation; near field filtered back projection method; near field imaging method; nonuniform fast Fourier transformation; target scattering diagnostics; Computed tomography; Interpolation; Radar antennas; Radar imaging; Spline; Non-uniform fast Fourier transformation; filtered back projection; near-field; tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Technology & Computational Electromagnetics (ICMTCE), 2011 IEEE International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-8556-7
  • Type

    conf

  • DOI
    10.1109/ICMTCE.2011.5915174
  • Filename