• DocumentCode
    1834717
  • Title

    Micro-scale 2D mapping of cadmium-zinc telluride strip detectors

  • Author

    Camarda, Giuseppe S. ; Kakuno, Edson M. ; Carini, Gabriella ; Bolotnikov, A.E. ; Wright, G.W. ; James, R.B. ; Siddons, D. Peter

  • Author_Institution
    Nat. Synchrotron Light Source, Brookhaven Nat. Lab., Upton, NY, USA
  • Volume
    5
  • fYear
    2003
  • fDate
    19-25 Oct. 2003
  • Firstpage
    3503
  • Abstract
    We had begun a program to develop CZT-based detectors optimized for synchrotron radiation (SR) applications. We have made a large number of pixellated and strip detectors with each element having a performance similar to that of individual commercial detectors. On the macroscopic scale it seems very hard to find a systematic correlation between performance and material defects, probably because of local stoichiometry variations and other local disordering. In order to understand the factors limiting the energy resolution of CZT X-ray detectors, our efforts were directed to the area of material characterization and detector testing using the National Synchrotron Light Source (NSLS). NSLS provides us with a highly collimated high intensity X-ray beam, which is employed to perform micro-scale stoichiometry measurement using the SR beam to excite fluorescence and using the characteristic line intensities to measure concentration. Micron-scale detector performance mapping is performed to measure the correlation between microscopic defects and fluctuations in collected charge.
  • Keywords
    X-ray detection; position sensitive particle detectors; semiconductor counters; synchrotron radiation; CZT X-ray detectors; CZT-based detectors; National Synchrotron Light Source; cadmium-zinc telluride strip detectors; energy resolution; fluorescence excitation; high intensity X-ray beam; local disordering; local stoichiometry variations; material characterization; microscale 2D mapping; microscale stoichiometry measurement; microscopic defects; microscopic fluctuations; pixellated detectors; synchrotron radiation applications; synchrotron radiation beam; Energy resolution; Light sources; Materials testing; Performance evaluation; Radiation detectors; Strips; Strontium; Synchrotron radiation; X-ray detection; X-ray detectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2003 IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-8257-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2003.1352666
  • Filename
    1352666