• DocumentCode
    1835616
  • Title

    CT Truncation artifact removal using water-equivalent thicknesses derived from truncated projection data

  • Author

    Maltz, J.S. ; Bose, S. ; Shukla, H.P. ; Bani-Hashemi, A.R.

  • Author_Institution
    Siemens Med. Solutions Inc., Concord
  • fYear
    2007
  • fDate
    22-26 Aug. 2007
  • Firstpage
    2907
  • Lastpage
    2911
  • Abstract
    Large patient anatomies and limited imaging fleld-of-view (FOV) lead to truncation of CT projections. Truncation introduces serious artifacts into reconstructed images, including central cupping and bright external rings. FOV may be increased using laterally offset detectors, but this requires sophisticated imaging hardware and full angular scanning. We propose a novel method to complete truncated projections based on the observation that the thickness of the patient may be estimated along the projection rays by calculating water-equivalent thicknesses (WET). These values are not at all affected by truncation and thus constitute valuable auxiliary information. We parameterize pairs of points along each ray that intersects the unknown object boundary. These points are separated by the measured WET value (obtained from projections that have been corrected for scatter and beam-hardening). We assume, for all large body parts, that the patient outline may be roughly approximated as an ellipse. Using a deterministic optimization algorithm, we simultaneously estimate the point positions and ellipse parameters by minimizing the distance between point sets and the ellipse boundary. The optimal ellipse is used to complete the truncated projections. Reconstruction then ensues. We apply the algorithm to a severely truncated CT dataset of a typical abdomen. The RMS error between complete data and truncated reconstructions (corrected using an empirical extrapolation approach) is 20.4% for an abdominal dataset. The new algorithm reduces this error to 1.0%. Even thought the algorithm assumes an elliptical patient cross-section, truly impressive increases in quantitative image quality are observed. The presence of pelvic bone in the image does not appreciably bias the ellipse position even though it does bias the thickness estimates for some rays. The algorithm incurs low computational cost and is suitable for on-line clinical workflows.
  • Keywords
    computerised tomography; image reconstruction; medical image processing; optimisation; CT projection truncation; CT truncation artifact removal; deterministic optimization algorithm; field of view; image reconstruction; patient crosssection elliptical approximation; patient thickness; reconstructed image artifacts; truncated projection data; water equivalent thickness; Abdomen; Anatomy; Computed tomography; Detectors; Error correction; Extrapolation; Hardware; Image quality; Image reconstruction; Scattering; Algorithms; Artifacts; Humans; Tomography, X-Ray Computed; Water;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
  • Conference_Location
    Lyon
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-0787-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2007.4352937
  • Filename
    4352937