• DocumentCode
    1835657
  • Title

    Comparison of analytical and algebraic 2D tomographic reconstruction approaches for irregularly sampled microCT data

  • Author

    Valton, S. ; Berard, P. ; Riendeau, J. ; Thibaudeau, C. ; Lecomte, R. ; Sappey-Marinier, D. ; Peyrin, F.

  • Author_Institution
    Univ. Claude Bernard-Lyon 1, Villeurbanne
  • fYear
    2007
  • fDate
    22-26 Aug. 2007
  • Firstpage
    2916
  • Lastpage
    2919
  • Abstract
    APD-based detectors with individual channel readout were developed for multi-crystal applications and have been implemented for the detection of annihilation radiation in the LabPETTM micro-scanner. The use of these APD-based detectors in X-ray imaging is currently being assessed with a microCT demonstrator in order to later combine PET and CT in one apparatus. This paper is focused on the tomographic reconstruction of the X-ray transmission data acquired with this demonstrator. Two aspects of the acquisition geometry need to be carefully considered: the radius of the detector arc and the irregular sampling of the detector bins. A specific shift- variant filtered backprojection formula derived to account for the detector curvature is applied to equiangularly resampled projection data while the simultaneous algebraic reconstruction technique is applied to both resampled and original projections. Images of physical phantoms reconstructed from measured projections using the different methods are presented and compared.
  • Keywords
    avalanche photodiodes; computerised tomography; data acquisition; image reconstruction; image sampling; medical image processing; phantoms; 2D tomographic reconstruction approach; APD-based detectors; LabPET microscanner; X-ray imaging; annihilation radiation; channel readout; detector arc radius; irregularly sampled microCT data; multicrystal applications; physical phantoms; shift-variant filtered backprojection; simultaneous algebraic reconstruction technique; Computed tomography; Geometry; Image reconstruction; Image sampling; Imaging phantoms; Positron emission tomography; Radiation detectors; X-ray detection; X-ray detectors; X-ray imaging; Radiographic Image Interpretation, Computer-Assisted; Tomography, X-Ray Computed;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
  • Conference_Location
    Lyon
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-0787-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2007.4352939
  • Filename
    4352939