DocumentCode :
1835991
Title :
Cosmic ray test system for the ATLAS thin gap chamber modules at KOBE
Author :
Suigmoto, T. ; Ochi, A. ; Arataki, Y. ; Bando, T. ; Homma, Y. ; Ichimiy, R. ; Ikeno, M. ; Ishii, K. ; Ishino, M. ; Iwasaki, H. ; Kurashiga, H. ; Mima, T. ; Miyazaki, Y. ; Nakagawa, Y. ; Nakaune, Y. ; Nozaki, M. ; Ohshita, H. ; Okumura, K. ; Sasaki, O. ; S
Author_Institution :
Graduate Sch. of Sci. & Technol., Kobe Univ., Japan
Volume :
5
fYear :
2003
fDate :
19-25 Oct. 2003
Firstpage :
3740
Abstract :
Thin gap chamber modules giving function of forward muon trigger to the ATLAS detector in the LHC experiment have been constructed at High Energy Research Organization (KEK) in Japan and their performances have been checked at Kobe University. A large-scale test system specially designed for measuring uniformity of the detection efficiencies and the timing resolution of 8 TGC modules at the same time was successfully operated. Each TGC module had 72 anode wire channels and 64 cathode strip channels (in total 1088 readout channels for 8 modules). Drift tubes consisted of 12 layers (total 428 tubes), between which the TGC modules are put, determined trajectories of cosmic rays. Hit pattern and timing of all detector signals (Trigger counter. Drift tubes and TGCs) were measured by using VME modules. In regular data acquisition situation, i.e. about effective 19 Hz trigger rate from scintillation counters and 73% tracking efficiency by the drift tubes, the detection efficiency of each layer by 5 mm × 5 mm region of 8 TGC modules (24 layers) was measured using about 7 million cosmic ray tracks per module in 10 days. 306 modules were already inspected at June 2003.
Keywords :
anodes; cathodes; cosmic ray apparatus; data acquisition; drift chambers; particle tracks; scintillation counters; 10 day; 19 Hz; 5 mm; 73 percent; ATLAS detector; ATLAS thin gap chamber modules; High Energy Research Organization; KEK; Kobe University; LHC experiment; TGC modules; VME modules; anode wire channels; cathode strip channels; cosmic ray test system; cosmic ray tracks; cosmic ray trajectories; data acquisition; detection efficiency uniformity; detector signal timing; drift tubes; effective trigger rate; forward muon trigger; hit pattern; large-scale test system; readout channels; scintillation counters; timing resolution; tracking efficiency; trigger counter; Anodes; Energy resolution; Large Hadron Collider; Large-scale systems; Mesons; Solid scintillation detectors; System testing; Time measurement; Timing; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2003 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8257-9
Type :
conf
DOI :
10.1109/NSSMIC.2003.1352719
Filename :
1352719
Link To Document :
بازگشت