• DocumentCode
    1838469
  • Title

    "Extracting the Required Reflection to Compensate the Sealed Connector of a Microstrip Fixture"

  • Author

    Stinehelfer, Harold E., Sr.

  • Author_Institution
    Made-it Associates, Inc. 40 West St. Lunenburg, MA 01462
  • Volume
    22
  • fYear
    1992
  • fDate
    Dec. 1992
  • Firstpage
    189
  • Lastpage
    197
  • Abstract
    The microstrip test fixture with sealed connectors was tested and converted to the time domain to reveal the reflections at each connector. The MAMA program was used to make the measurements using the new hp8510c analyzer and the PC-486 controller. This is an experimental micro strip line in an empty box housing. A capacitive demonstration file was then used to modify the connectors by "injecting" into the experiment a capacitive reflection. The results gave the same result as if an actual capacitance had been added to the test fixture connector.
  • Keywords
    Capacitance; Connectors; Fixtures; Frequency measurement; Inductance; Insertion loss; Loss measurement; Microstrip; Reflection; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    ARFTG Conference Digest-Fall, 40th
  • Conference_Location
    Orlando, FL, USA
  • Print_ISBN
    0-7803-5686-1
  • Type

    conf

  • DOI
    10.1109/ARFTG.1992.326985
  • Filename
    4119671