    Whole body PET using overlapped 3D acquisition and weighted image summation

  • Author

    Schubert, Scott F. ; Pajevic, Sinisa ; Carson, Richard E.

  • Author_Institution
    GE Med. Syst., Milwaukee, WI, USA
  • Volume
    2
  • fYear
    1996
  • fDate
    2-9 Nov 1996
  • Firstpage
    1285
  • Abstract
    In whole body 3D PET, acquiring at distinct bed positions results in an axially varying sensitivity profile due to the cylindrical geometry and axial sampling pattern of the tomograph. Overlapping the end slices of bed positions can minimize the axial nonuniformity of the noise. We present an algorithm for the weighted summation of overlapped images, where the summation is performed after tomographic reconstruction. The weights are chosen to minimize the variance of the summed image, and are based on the noise equivalent counts in the images and the slice-to-slice coefficients of variation of a uniform cylinder. The optimal overlap is obtained and is 3-5 slices (9-15% system axial field of view) for ramp filters at Nyquist on the GE Advance tomograph in 3D mode. This overlap is smaller than the axial sensitivity profile suggests, due to the smoothing of the end slices in the 3D reprojection algorithm. The optimal overlap is independent of axial filter (due to all slices being smoothed equally); however, the optimal overlap increases as transverse smoothing is increased, because the smoothed noise profile is more consistent with what the axial sensitivity profile suggests. As compared to continuous bed motion, overlapping using weighted image summation requires no specialized acquisition software or reconstruction corrections
  • Keywords
    data acquisition; image reconstruction; medical image processing; positron emission tomography; axial filter; axial nonuniformity; axial sampling pattern; axially varying sensitivity profile; continuous bed motion; cylindrical geometry; optimal overlap; overlapped 3D acquisition; overlapped images; ramp filters; slice-to-slice coefficients of variation; smoothed noise profile; tomographic reconstruction; weighted image summation; weighted summation; whole body PET; Biomedical imaging; Filters; Geometry; Image reconstruction; Image sampling; Imaging phantoms; Sampling methods; Smoothing methods; Tomography; Whole-body PET;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-3534-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1996.591681
  • Filename
    591681