DocumentCode
1839333
Title
Verification of LRRM Calibrations with Load Inductance Compensation for CPW Measurements on GaAs Substrates
Author
Pence, J.E.
Author_Institution
Cascade Microtech, 14255 SW Brigadoon Ct., Beaverton, OR 97005
Volume
24
fYear
1993
fDate
Dec. 1993
Firstpage
45
Lastpage
47
Abstract
The microwave on-wafer measurement community has been searching for a mechanism to quantify calibration inaccuracies. Recent work at the National Institute of Standards and Technology (NIST) has enabled the determination of calibration error bounds by comparison with a well understood technique - the NIST multi-line GaAs TRL calibration. A series of automated Line-Reflect-Reflect-Match (LRRM) calibrations with load inductance compensation were performed on commercially available alumina coplanar waveguide standards. These calibrations were then compared with an NIST calibration. The calculated error bounds were determined and compared in order to assess both the relative accuracy and the repeatability of the automated calibrations.
Keywords
Calibration; Coplanar waveguides; Gallium arsenide; Inductance measurement; Measurement standards; Microwave measurements; NIST; Performance evaluation; Probes; Software packages;
fLanguage
English
Publisher
ieee
Conference_Titel
ARFTG Conference Digest-Fall, 42nd
Conference_Location
San Jose, CA, USA
Print_ISBN
0-7803-5686-1
Type
conf
DOI
10.1109/ARFTG.1993.327040