DocumentCode
1841605
Title
Optimizing Time-Domain Network Analysis
Author
DeGroot, Donald C. ; Marks, Roger B.
Author_Institution
National Institute of Standards and Technology, Microwave Metrology Group, Mail Code 813.06, 325 Broadway, Boulder, CO 80303-3328, (303) 497-7212 degroot@boulder.nist.gov
Volume
28
fYear
1995
fDate
Nov. 1995
Firstpage
19
Lastpage
28
Abstract
In this work, we demonstrate how changes in sample density, time-window size, and waveform averaging affect the accuracy and acquisition time of calibrated time-domain network analysis. One of the key results from this study is that accuracy can be enhanced by eliminating the incident step-edge signal from the time-domain reflection waveform before maximizing the instrument´s vertical scale. This study identifies the trade-offs between accuracy and measurement speed and examines other trends to provide general guidance in establishing reliable and efficient time-domain network analysis measurements for a variety of rf and microwave applications.
Keywords
Calibration; Coplanar waveguides; Instruments; Microwave measurements; NIST; Oscilloscopes; Probes; Reflection; Time domain analysis; Velocity measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
ARFTG Conference Digest-Fall, 46th
Conference_Location
Scottsdale, AZ, USA
Print_ISBN
0-7803-5686-1
Type
conf
DOI
10.1109/ARFTG.1995.327128
Filename
4119806
Link To Document