• DocumentCode
    1841907
  • Title

    Removal of cable and connector dispersion in time-domain waveform measurements on 40 Gb integrated circuits

  • Author

    Scott, J. ; Behnia, B. ; Bossche, M.V. ; Cognata, A. ; Verspecht, J. ; Verbeyst, F. ; Thorn, M. ; Scherrer, D.R.

  • Author_Institution
    Agilent Technol., Santa Rosa, CA, USA
  • Volume
    3
  • fYear
    2002
  • fDate
    2-7 June 2002
  • Firstpage
    1669
  • Abstract
    A new instrument for time-domain characterization of circuits is illustrated. We measure output waveshape and rise time of two high-speed digital circuits on wafer, using a 50 GHz prototype of the new instrument. It uses vector error-correction to de-embed the component under test like a network analyzer but reads out in the time-domain after the fashion of an equivalent-time oscilloscope. With the calibration plane of the instrument set at the tips of the wafer probes, errors arising from dispersion in the connection hardware are removed. A further benefit of this instrument is that random jitter is removed without the convolution penalty usually incurred by averaging, so that anomalies such as pattern dependent jitter are exposed. The system risetime is 7 ps, compared to a system risetime of 12-13 ps for a conventional equivalent-time oscilloscope of the same bandwidth in the presence of wafer probes, bias networks, and cables.
  • Keywords
    calibration; digital integrated circuits; error correction; high-speed integrated circuits; integrated circuit testing; jitter; network analysers; probes; time-domain analysis; waveform analysis; 12 to 13 ps; 40 Gbit/s; 50 GHz; 7 ps; bias networks; cable dispersion removal; cables; component under test de-embedding; connection hardware dispersion; connector dispersion removal; dispersion errors; equivalent-time oscilloscope; high-speed digital circuits; instrument calibration plane; integrated circuits; network analyzer; on-wafer measurements; output waveshape; pattern dependent jitter; random jitter removal; rise time; system risetime; time-domain characterization instrument; time-domain read-out; time-domain waveform measurements; vector error-correction; wafer probes; Circuit testing; Connectors; Digital circuits; Instruments; Jitter; Oscilloscopes; Probes; Prototypes; Time domain analysis; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest, 2002 IEEE MTT-S International
  • Conference_Location
    Seattle, WA, USA
  • ISSN
    0149-645X
  • Print_ISBN
    0-7803-7239-5
  • Type

    conf

  • DOI
    10.1109/MWSYM.2002.1012179
  • Filename
    1012179