• DocumentCode
    1841960
  • Title

    A SAR test procedure for wireless devices with simultaneous multi-band transmission

  • Author

    Siegbahn, M. ; Tornevik, C.

  • Author_Institution
    Ericsson Res., Ericsson AB, Stockholm, Sweden
  • Volume
    2
  • fYear
    2003
  • fDate
    22-27 June 2003
  • Firstpage
    1033
  • Abstract
    In this paper a procedure for SAR (specific absorption rate) testing of wireless devices with simultaneous transmission in multiple bands is presented. The approach of this test procedure is to measure SAR for the transmitters in the device separately, add the measured SAR distributions and then finally calculate the 1 g and 10 g mass averaged SAR from the resulting distribution. The procedure has been tested successfully on a number of devices including a GSM mobile phone with an integrated long-range Bluetooth transmitter.
  • Keywords
    Bluetooth; cellular radio; electromagnetic wave absorption; mobile handsets; radio transmitters; GSM mobile phone; SAR test procedure; integrated long-range Bluetooth transmitter; mass averaged SAR; simultaneous multiband transmission wireless devices; specific absorption rate; transmitter SAR measurement; Frequency measurement; GSM; Imaging phantoms; Liquids; Mobile handsets; Probes; Radio frequency; Specific absorption rate; Testing; Transmitters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation Society International Symposium, 2003. IEEE
  • Conference_Location
    Columbus, OH, USA
  • Print_ISBN
    0-7803-7846-6
  • Type

    conf

  • DOI
    10.1109/APS.2003.1219411
  • Filename
    1219411