• DocumentCode
    1842613
  • Title

    Dynamic spectral measurements on high-power oscillators in the millimeter-wave domain

  • Author

    Schlaich, Andreas ; Gantenbein, Gerd ; Kern, Stefan ; Thumm, Manfred

  • Author_Institution
    Inst. fur Hochfrequenztech. und Elektron. (IHE), Karlsruhe Inst. of Technol. (KIT), Karlsruhe, Germany
  • fYear
    2012
  • fDate
    12-14 March 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    At KIT, high power millimeterwave oscillators (gyrotrons) for plasma physics heating and current drive experiments are developed and tested. This paper describes the introduction and application of a time-based measurement system which allows broadband high-dynamic range spectrum analysis of the gyrotron output signal in the range 110-170 GHz.
  • Keywords
    gyrotrons; millimetre wave oscillators; plasma radiofrequency heating; spectral analysis; KIT; broadband high-dynamic range spectrum analysis; current drive experiment; dynamic spectral measurements; frequency 110 GHz to 170 GHz; gyrotron output signal; high-power millimeter-wave oscillator; plasma physics heating; time-based measurement system; Bandwidth; Dynamic range; Gyrotrons; Modulation; Oscillators; Radio frequency; Spectrogram; FFT; gyrotron; oscilloscope; spectrogram; spectrum analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference (GeMiC), 2012 The 7th German
  • Conference_Location
    Ilmenau
  • Print_ISBN
    978-1-4577-2096-3
  • Electronic_ISBN
    978-3-9812668-4-9
  • Type

    conf

  • Filename
    6185188