DocumentCode
1844670
Title
Impact of non-simultaneous P/f and Q/V grid code requirements on PV inverters on unintentional islanding operation in distribution network
Author
Lissandron, Stefano ; Sgarbossa, Riccardo ; Dalla Santa, Luca ; Mattavelli, Paolo ; Turri, Roberto ; Cerretti, Alberto
Author_Institution
Dept. of Inf. Eng., Univ. of Padova, Padua, Italy
fYear
2015
fDate
22-25 June 2015
Firstpage
1
Lastpage
7
Abstract
The analysis of unintentional islanding in distribution grids with a large penetration of renewable energy sources is of increasing interest due to the recently introduced requirements of P/f and Q/V supporting capabilities of Distributed Energy Resources (DERs) and the wider frequency and voltage ranges, DERs should be able to operate with, before protection tripping. DER anti-islanding protections, if present, may fail to detect this grid transition and so uncontrolled islanding operation may appear. Since this operating mode may be dangerous for the electric network operation and may cause damages for the grid equipment, in this paper the increase of its risk due to P/f and Q/V droop characteristics of generators is addressed. Analytic results are initially derived for the steady-state unintentional islanding operation and then they are validated on a laboratory-scale grid setup. The proposed investigation will show that the risk of permanent unintentional islanding increases introducing P/f or Q/V droop regulation and that such risk is maximum including both the P/f and Q/V droop regulations, rather than only one of them.
Keywords
distributed power generation; invertors; power apparatus; power distribution faults; power distribution reliability; power grids; renewable energy sources; solar cells; DER antiislanding protection; P-f droop regulation; PV inverter; Q-V droop regulation; distributed energy resource; distribution grid transition; distribution network; electric network operation; grid equipment; nonsimultaneous P-f grid code requirement; nonsimultaneous Q-V grid code requirement; protection tripping; renewable energy source; steady-state unintentional islanding operation; Density estimation robust algorithm; Inverters; Islanding; Reactive power; Steady-state; Threshold voltage; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics for Distributed Generation Systems (PEDG), 2015 IEEE 6th International Symposium on
Conference_Location
Aachen
Type
conf
DOI
10.1109/PEDG.2015.7223095
Filename
7223095
Link To Document