• DocumentCode
    1849123
  • Title

    Aberration measurement of fast pulse generators using sampling oscilloscopes

  • Author

    Smith, Andrew J A ; Roddie, Alan G ; Woolliams, Peter D. ; Harper, Matthew R

  • Author_Institution
    Centre for Electromagnetic and Time Metrology National Physical Laboratory, Teddington, Middlesex, United Kingdom TW11 0LW, e-mail: andrew.smith@npl.co.uk
  • Volume
    38
  • fYear
    2000
  • fDate
    Nov. 2000
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The definition, measurement, and traceability of aberrations in pulse waveform metrology is discussed. The use of reference waveforms and masks allows the definition of aberrations within specific regions relative to the transition point of a pulse generator, as desired by manufacturers and users. Of particular importance is the definition of aberrations for specific bandwidths, often required by the end user. An attempt has been made to identify anomalous structure and its source, whether in the oscilloscope or pulse generator. By using the information obtained it is now possible to correct a pulse generator waveform to a much more realistic shape and with a better correspondence to dc amplitude calibration values.
  • Keywords
    Bandwidth; Calibration; Filters; Laboratories; Manufacturing; Oscilloscopes; Pulse generation; Pulse measurements; Sampling methods; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    ARFTG Conference Digest-Fall, 56th
  • Conference_Location
    Boulder, AZ, USA
  • Print_ISBN
    0-7803-5686-1
  • Type

    conf

  • DOI
    10.1109/ARFTG.2000.327444
  • Filename
    4120143