DocumentCode :
1852462
Title :
Evaluation of silicon micro strip detectors with large read-out pitch
Author :
Hazumi, M. ; Kawasaki, T. ; Senyo, K. ; Nagashima, Y. ; Yamamoto, K. ; Yamamura, K. ; Tsuboyama, T. ; Haba, J. ; Ikeda, H. ; Iwasaki, H. ; Matsuda, T. ; Ozaki, H. ; Tanaka, M. ; Yamada, Y. ; Okuno, S. ; Avrillon, S. ; Asano, Y. ; Mori, S. ; Fukunaga, C. ;
Author_Institution :
Inst. of Phys., Osaka Univ., Japan
Volume :
1
fYear :
1995
fDate :
21-28 Oct 1995
Firstpage :
515
Abstract :
For the development of the silicon micro strip detector with the pitch of the readout strips as large as 250 μm on ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips
Keywords :
position sensitive particle detectors; silicon radiation detectors; 250 mum; Al; Si; aluminum read-out strips; charge collection; implant strips; large read-out pitch; silicon micro strip detectors; Capacitance; Detectors; Implants; Photonics; Physics; Silicon; Spatial resolution; Strips; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
Conference_Location :
San Francisco, CA
Print_ISBN :
0-7803-3180-X
Type :
conf
DOI :
10.1109/NSSMIC.1995.504279
Filename :
504279
Link To Document :
بازگشت