Abstract
Industrial chemical processes are usually very complex, making the control a challenging task. The 13C isotope separation process is highly nonlinear, with slow dynamics and large time delays. Based on previous research and by experimental knowledge it was determined that secondary processes, like boiler carbon monoxide level or condenser liquid nitrogen level, play an important role in the satisfactory operation of the separation column. This paper focuses on the boiler carbon monoxide level and proposes a control solution for the boiler heating. The proposed solution is based on an original version of power transducer and is implemented and tested using Matlab/SIMULINK environment. Simulation results are provided to demonstrate the effectiveness of the proposed solution.
Keywords
boilers; chemical engineering; delays; power control; 13C isotope separation column boiler supply; Matlab; SIMULINK; boiler carbon monoxide level; boiler heating; condenser liquid nitrogen level; power transducer; time delays; variable DC power sources; Boilers; Integrated circuit modeling; Isotopes; Resistors; Transducers; Voltage control; boiler heating; cryogenic distillation columns; variable DC power source;
fLanguage
English
Publisher
ieee
Conference_Titel
System Theory, Control and Computing (ICSTCC), 2014 18th International Conference
Conference_Location
Sinaia
Type
conf
DOI
10.1109/ICSTCC.2014.6982428
Filename
6982428
Link To Document