DocumentCode
1854934
Title
Insulation system reliability in wind generation
Author
Penrose, Howard W.
Author_Institution
Success by Design, Lombard, IL, USA
fYear
2015
fDate
7-10 June 2015
Firstpage
358
Lastpage
361
Abstract
Wind turbine generators are subjected to unusual environments and stresses. In this paper we will discuss several types of wind generator insulation failure mechanisms as well as forensic analysis results of several different manufacturers´ systems. The types of generators studied include induction, wound rotor, and permanent magnet across a number of output voltages and environmental conditions. Past studies relied upon rudementary results and stopped at the obvious. In this paper we will dig a little deeper into the failure processes observed.
Keywords
fault diagnosis; induction motors; machine insulation; permanent magnets; power system faults; power system reliability; rotors; wind turbines; forensic analysis; induction rotor; insulation system reliability; permanent magnet; wind generation; wind generator insulation failure mechanisms; wind turbine generators; wound rotor; Contamination; Electric potential; Forensics; Generators; Reliability; Transient analysis; alternative energy; environment; forensics; generator; insulation system; root cause analysis; wind generation;