DocumentCode
1855926
Title
Heart Rate Detection from an Electronic Weighing Scale
Author
Gonzalez-Landaeta, R. ; Casas, O. ; Pallas-Areny, R.
Author_Institution
Univ. Politec. de Catalunya, Barcelona
fYear
2007
fDate
22-26 Aug. 2007
Firstpage
6282
Lastpage
6285
Abstract
We propose a novel technique for heart rate detection on a subject that stands on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear, and does not require any sensors attached to the body. We have applied our method to three different weighing scales, and estimated whether their sensitivity and frequency response suited heart rate detection. Scale sensitivities were from 490 nV/V/N to 1670 nV/V/N, all had an underdamped transient response and their dynamic gain error was below 19 % at 10 Hz, which are acceptable values for heart rate estimation. We also designed a pulse detection system based on off-the-shelf integrated circuits, whose gain was about 70 times 103 and able to sense force variations about 240 mN. The signal-to-noise ratio (SNR) of the main peaks of the pulse signal detected was higher than 48 dB, which is large enough to estimate the heart rate by simple signal processing methods. To validate the method, the ECG and the force signal were simultaneously recorded on 12 volunteers. The maximal error obtained from heart rates determined from these two signals was plusmn0.6 beats/minute.
Keywords
bioelectric phenomena; biomedical measurement; blood; electrocardiography; force measurement; haemodynamics; medical signal detection; medical signal processing; ECG; aorta; blood acceleration; dynamic gain error; electronic weighing scale; force signal; force variation sensing; heart rate detection; off-the-shelf integrated circuits; pulse detection system; signal processing; signal-to-noise ratio; underdamped transient response; Acceleration; Blood; Footwear; Force sensors; Frequency estimation; Frequency response; Heart rate; Heart rate detection; Signal processing; Transient response; Ballistocardiography; Electrocardiography; Equipment Design; Equipment Failure Analysis; Heart Rate; Humans; Manometry; Reproducibility of Results; Sensitivity and Specificity; Weight-Bearing;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE
Conference_Location
Lyon
ISSN
1557-170X
Print_ISBN
978-1-4244-0787-3
Type
conf
DOI
10.1109/IEMBS.2007.4353791
Filename
4353791
Link To Document