Abstract
Remnant life assessment of old power apparatus is often desired for decision regarding replacement/renovation program. In absence of any previous data of testing, life assessment prediction is difficult. However certain condition assessment tests can reveal comparative status of its critical component (mainly insulation system). This testing, if done as per laid down procedures, can help in fairly reasonable life prediction for particularly old machines which has out-lived its design life. This paper covers a case study related to electrical generators installed at coal fields in Eastern India
Keywords
condition monitoring; electric generators; machine testing; remaining life assessment; Eastern India; condition assessment tests; condition monitoring; electrical diagnostic testing; electrical generators; insulation system; life prediction; old power apparatus; remnant life assessment; replacement-renovation program; Computer aided software engineering; Condition monitoring; Electrical resistance measurement; Insulation testing; Partial discharge measurement; Power generation; Rotating machines; System testing; Thermal stresses; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Conference, 2005. IPEC 2005. The 7th International
Conference_Location
Singapore
Print_ISBN
981-05-5702-7
Type
conf
DOI
10.1109/IPEC.2005.206873
Filename
1627162
Link To Document