Title :
The research of demarcating and evaluating method of system error of mobile station
Author :
Weijin Qin ; Pei Wei ; Xiaoqian Ren ; Xuhai Yang ; Hong Chang
Author_Institution :
Key Lab. of Precision Navig. & Timing, Nat. Time Service Center, Xi´an, China
Abstract :
The maximum error of time comparison of multiple stations is the time delay error of equipment. This paper demarcate relative deviation of multiple stations with mobile station, testing and evaluate system difference with the closure principle of three stations, this method can effectively demarcate system difference of multiple station, the accuracy is better than 1ns.
Keywords :
delays; mobile satellite communication; synchronisation; demarcating method; evaluating method; mobile station; system error; time comparison; time delay error; Calibration; Delays; Earth; Ionosphere; Mobile communication; Sagnac interferometers; Satellites; demarcate method and evaluate method of system error of multiple station; mobile station calibration; two-way satellite time-comparision;
Conference_Titel :
Frequency Control Symposium (FCS), 2014 IEEE International
Conference_Location :
Taipei
DOI :
10.1109/FCS.2014.6859958