    Surface charge decay under the influence of prior applied voltage in freon

  • Author

    Elkhodary, S.M. ; Hackam, R.

  • Author_Institution
    Dept. of Electr. Eng., Windsor Univ., Ont., Canada
  • fYear
    1994
  • fDate
    23-26 Oct 1994
  • Firstpage
    749
  • Lastpage
    754
  • Abstract
    The application of high voltage to an insulating spacer causes a generation of charges within and on the insulator. These charges distort the electric field and may result in a significant modification of the withstand voltage. The decay of the charge density subsequent to removal of the applied voltage is reported. At a fixed pressure the rate of charge decay increased with increasing pre-applied voltage. At a fixed pre-applied voltage, the rate of charge decay increased with increasing gas pressure
  • Keywords
    gaseous insulation; electric field; freon; gas pressure; insulating spacer; pre-applied voltage; surface charge decay; withstand voltage; Cathodes; Conducting materials; Conductivity; Dielectrics and electrical insulation; Electrodes; Flashover; Gas insulation; Glass; Probes; Voltage;