• DocumentCode
    1862720
  • Title

    Concentrated Wound 45 kW, 420 rpm Permanent Magnet Machine with Embedded Magnets

  • Author

    Salminen, P. ; Niemela, M. ; Jussila, H. ; Pyrhonen, Juha ; Mantere, Juhani

  • Author_Institution
    Lappeenranta University of Technology, Department of Electrical Engineering, P.O. Box 20, 53851 Lappeenranta, Finland, phone: (+3585)6216780, email: pia.salminen@lut.fi
  • fYear
    2006
  • fDate
    4-6 April 2006
  • Firstpage
    494
  • Lastpage
    498
  • Abstract
    A 45 kW prototype machine with 12-slot-10-pole, q = 0.4 structure was constructed in order to obtain practical experiences of concentrated wound PM-machines. The measurement results provide essential information to verify the analytical calculations and also the results obtained with 2D FEA. The winding type studied consists of concentrated pole windings. The number of slots per pole and phase q < 0.5. Concentrated wound motors create harmonics and sub-harmonics, which may cause extra heating, additional losses and vibration. Therefore, the importance of manufacturing a prototype machine of considerable power e.g. 45 kW should be stressed. It was in the authors´ interest to verify if the harmonics have a great impact on the losses.
  • Keywords
    Permanent magnet motor; concentrated wound; embedded magnets;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics, Machines and Drives, 2006. The 3rd IET International Conference on
  • Conference_Location
    The Contarf Castle, Dublin, Ireland
  • Print_ISBN
    0-86341-609-8
  • Type

    conf

  • Filename
    4123572