DocumentCode
1862851
Title
Comparison of Stray Load and Inverter-Induced Harmonic Losses in Induction Motors Using Calorimetric and Harmonic Injection Methods
Author
Cao, Wanli ; Bradley, K.J. ; Magill, R. ; Clare, Jon C. ; Wheeler, Pat
Author_Institution
School of Electrical and Electronic Engineering, the University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
fYear
2006
fDate
4-6 April 2006
Firstpage
520
Lastpage
525
Abstract
This paper addresses two types of additional losses in induction motors. One is stray load loss resulting from loss segregation when induction motors operate from a sinusoidal supply voltage and the other is harmonic loss when induction motors operate from inverter-fed supply voltage. Both losses are of concern in machine design and operation but they are difficult to predict accurately without the use of empirical factors. This is due to their complex loss mechanisms and small magnitudes in most cases. Investigation into the correlation of the two loss components could enable effective quality control of the manufacturing of machines for use on inverter supplies. With the availability of advanced calorimetric and harmonic injection techniques, it becomes possible for these small loss components to be measured with precision. In this paper, seven induction motors ranging in power through 1.1, 7.5, 15 to 30 kW are tested for experimental comparison. Among these are four 7.5 kW machines. Test results suggest there is a need for induction motors designed specifically for inverter-fed operation.
Keywords
Additional loss; calorimetry; converter drive; harmonic analysis; induction motor;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives, 2006. The 3rd IET International Conference on
Conference_Location
The Contarf Castle, Dublin, Ireland
Print_ISBN
0-86341-609-8
Type
conf
Filename
4123577
Link To Document