• DocumentCode
    1862851
  • Title

    Comparison of Stray Load and Inverter-Induced Harmonic Losses in Induction Motors Using Calorimetric and Harmonic Injection Methods

  • Author

    Cao, Wanli ; Bradley, K.J. ; Magill, R. ; Clare, Jon C. ; Wheeler, Pat

  • Author_Institution
    School of Electrical and Electronic Engineering, the University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
  • fYear
    2006
  • fDate
    4-6 April 2006
  • Firstpage
    520
  • Lastpage
    525
  • Abstract
    This paper addresses two types of additional losses in induction motors. One is stray load loss resulting from loss segregation when induction motors operate from a sinusoidal supply voltage and the other is harmonic loss when induction motors operate from inverter-fed supply voltage. Both losses are of concern in machine design and operation but they are difficult to predict accurately without the use of empirical factors. This is due to their complex loss mechanisms and small magnitudes in most cases. Investigation into the correlation of the two loss components could enable effective quality control of the manufacturing of machines for use on inverter supplies. With the availability of advanced calorimetric and harmonic injection techniques, it becomes possible for these small loss components to be measured with precision. In this paper, seven induction motors ranging in power through 1.1, 7.5, 15 to 30 kW are tested for experimental comparison. Among these are four 7.5 kW machines. Test results suggest there is a need for induction motors designed specifically for inverter-fed operation.
  • Keywords
    Additional loss; calorimetry; converter drive; harmonic analysis; induction motor;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics, Machines and Drives, 2006. The 3rd IET International Conference on
  • Conference_Location
    The Contarf Castle, Dublin, Ireland
  • Print_ISBN
    0-86341-609-8
  • Type

    conf

  • Filename
    4123577