• DocumentCode
    1863038
  • Title

    Implementation and Verification of CFL Models for Use in Performance Analysis in High Frequency Electronic Ballasts

  • Author

    Shafi, Mohsin Ayaz ; McMahon, R A

  • Author_Institution
    Engineering Department, University of Cambridge, Trumpington Street, Cambridge, CB2 1PZ, UK. Phone: +44 (0)1223 332768, Email: mas97@eng.cam.ac.uk
  • fYear
    2006
  • fDate
    4-6 April 2006
  • Firstpage
    561
  • Lastpage
    565
  • Abstract
    The performance of a 42 W compact fluorescent lamp and its associated electronic ballast has been simulated in PSPICE. Both behavioural and physics-based models for the lamp were considered and the former was found to give good results with the benefit of easy implementation. The predictions of circuit currents and losses closely match experimentally measured values. Losses were measured directly in a calorimeter. Using simulation to disaggregate the total loss figure, it is seen that the output resonant inductor makes the largest contribution to the total losses in the electronic ballast.
  • Keywords
    Calorimetric measurement; Compact fluorescent lamp; Electronic ballast;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics, Machines and Drives, 2006. The 3rd IET International Conference on
  • Conference_Location
    The Contarf Castle, Dublin, Ireland
  • Print_ISBN
    0-86341-609-8
  • Type

    conf

  • Filename
    4123585