DocumentCode :
186389
Title :
Improvement in read range of an UHF RFID newborn hospital monitoring system using meander line antennas
Author :
Lagunes-Aranda, Luis F. ; Carrion-Rivera, Luis E. ; Zamora-Mejia, Gregorio ; Gonzalez-Benitez, Ruben A. ; Martinez-Lopez, A.G. ; Martinez-Castillo, Jaime
Author_Institution :
Univ. Veracruzana, Veracruz, Mexico
fYear :
2014
fDate :
4-6 June 2014
Firstpage :
1
Lastpage :
6
Abstract :
Theft and exchange of newborns have rise its numbers becoming this topic a big issue that must be face up by hospitals. Closed Circuit Television (CCTV) surveillance is one of the most used solutions. However, CCTV needs human operator and a highly implementation cost. Ultra High Frequency Radio IDentification (UHF RFID) brings an easy and cheap solution to this problematic because of automatic real time control and monitoring of passive elements called tags. This work presents the design of two UHF RFID meander line antennas for newborn hospital monitoring applications. The first antenna is implemented on printed circuit board (PCB) obtaining a read range of 8.25m, a read range improvement of 2.25m is observed compared with commercially available passive systems. The second antenna is fabricated on Rogers Duroid 5880 flexible substrate allowing adhesion to any surface shape, a read range of 6m is obtained. Comercially available system used as reference is composed by a reader CSL 461 and passive tag Confidex Carrier. In order to illustrate this improvement, a monitoring system layout prototype is proposed.
Keywords :
UHF antennas; adhesion; biomedical electronics; biomedical engineering; hospitals; paediatrics; patient monitoring; printed circuits; radiofrequency identification; CCTV; Rogers Duroid 5880 flexible substrate; UHF RFID newborn hospital monitoring system; adhesion; automatic real time control; closed circuit television surveillance; commercially available passive systems; human operator; meander line antennas; monitoring system layout prototype; passive element monitoring; passive tag Confidex Carrier; printed circuit board; read range; reader CSL 461; surface shape; ultrahigh frequency radio identification; Dipole antennas; Hospitals; Monitoring; Object recognition; Pediatrics; Radiofrequency identification; GBW; Gain; Hospital; Meander Line Antenna; Newborn; Passive Tag; Reflection Coefficient; UHF RFID;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Communications and Computing (COLCOM), 2014 IEEE Colombian Conference on
Conference_Location :
Bogota
Print_ISBN :
978-1-4799-4342-5
Type :
conf
DOI :
10.1109/ColComCon.2014.6860415
Filename :
6860415
Link To Document :
بازگشت