Abstract :
The shape and size of the transverse phase space injected into a storage ring can be deduced from turn-by-turn measurements of the transient behavior of the beam envelope in the ring. Envelope oscillations at 2× the β-tron frequency indicate the presence of a β-mismatch, while envelope oscillations at the β-tron frequency are the signature of a dispersion function mismatch. Experiments in injection optimization using synchrotron radiation imaging of the beam and a fast-gated camera at the SLC damping rings are reported
Keywords :
electron accelerators; particle beam injection; particle beam stability; storage rings; SLC damping rings; beam envelope; beta-mismatch; betatron frequency; dispersion function mismatch; fast-gated camera; injection envelope matching; injection optimization; storage rings; transient behavior; transverse phase space; turn-by-turn measurements; Cameras; Damping; Frequency; Lattices; Linear accelerators; Particle beams; Phase measurement; Shape measurement; Size measurement; Storage rings;