• DocumentCode
    1868210
  • Title

    The investigation of Active VC and EBAC analysis utilization on test structure

  • Author

    Link Chang ; Kuo Yu Wang ; Wang, Simon T. C. ; Yu Pang Chang

  • Author_Institution
    United Microelectron. Corp., Ltd., Tainan, Taiwan
  • fYear
    2015
  • fDate
    June 29 2015-July 2 2015
  • Firstpage
    205
  • Lastpage
    208
  • Abstract
    As the founded of nano-probing technique on Scanning Electron Microscope (SEM) base system, the Active Voltage Contrast (AVC) and electron beam absorbed current (EBAC) technique are easier to apply on failure analysis. Both these two can isolate failure location accurately, and high resistance site also can be located by these powerful tools. Based on passed analysis experience, we will investigate and present the utilization of these two techniques to develop the better condition. By the investigating on test circuit of metal/via chain, the better effective analysis skill can be applied to the related high resistance failure analysis.
  • Keywords
    failure analysis; integrated circuit reliability; integrated circuit testing; scanning electron microscopy; EBAC analysis utilization; active voltage contrast; electron beam absorbed current technique; high resistance failure analysis; metal-via chain; nanoprobing technique; scanning electron microscope; test structure; Automatic voltage control; Electron beams; Failure analysis; Metals; Probes; Resistance; Scanning electron microscopy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits (IPFA), 2015 IEEE 22nd International Symposium on the
  • Conference_Location
    Hsinchu
  • Type

    conf

  • DOI
    10.1109/IPFA.2015.7224372
  • Filename
    7224372