DocumentCode :
1869767
Title :
Measurements of harmonic distortion produced by a saturated optical amplifier with a nonlinear microwave network analyzer
Author :
Vael, Philip ; Rolain, Yves ; Barel, Alain ; Bliki, Andy
Author_Institution :
Vrije Univ., Brussels, Belgium
Volume :
1
fYear :
1998
fDate :
18-21 May 1998
Firstpage :
581
Abstract :
This paper presents a method to measure the harmonic distortion produced by optical amplifiers. Therefore, a recently developed Nonlinear-Network Measurement System has been extended with a laser source and a detector. A proposal for shifting the absolute calibration plane from the electrical to the optical plane is given. The experimental results show that the saturated optical amplifier does not significantly increase the harmonic distortion of the applied modulated optical input signal
Keywords :
calibration; electric distortion measurement; harmonic distortion; microwave measurement; network analysers; optical fibre testing; optical saturation; absolute calibration plane; detector; harmonic distortion; laser source; modulated optical input signal; nonlinear microwave network analyzer; nonlinear-network measurement; saturated optical amplifier; Distortion measurement; Harmonic distortion; Laser noise; Optical amplifiers; Optical distortion; Optical modulation; Optical saturation; Proposals; Semiconductor optical amplifiers; Stimulated emission;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 1998. IMTC/98. Conference Proceedings. IEEE
Conference_Location :
St. Paul, MN
ISSN :
1091-5281
Print_ISBN :
0-7803-4797-8
Type :
conf
DOI :
10.1109/IMTC.1998.679858
Filename :
679858
Link To Document :